Fire-safety self-inspection

Fire Safety Inspection Generator

Tick the fire-safety features and systems your building actually has, and this assembles a tailored, numbered, print-ready self-inspection checklist — each system with its concrete walk-round checks. Use it to build a monthly routine. It is an indicative planning aid, not a statutory fire audit, and it runs entirely in your browser.

What does this building have?

Tick everything present — sprinklers and kitchen/gas are off by default as many buildings don’t have them. Each tick adds that system’s section to the checklist below.

0
Check items
0
Sections
Your walk-round has 36 items across 8 systems. Mark each Pass, Fail or N/A, then date and sign.

A routine self-inspection catches the easy failures — a discharged extinguisher, a blocked exit, a fault lamp — between the formal checks. It never replaces them.

Fire-Safety Inspection Checklist

36 items · 8 sections

Building / area:  
Date:     Inspector:  

Portable fire extinguishers

  • 1.Pressure gauge needle sits in the green band P F N/A
  • 2.Safety pin and tamper seal are intact P F N/A
  • 3.Within its refill / last-service date on the tag P F N/A
  • 4.Wall-mounted, clearly signed and unobstructed P F N/A
  • 5.Right type for the risk nearby (e.g. CO2/DCP near electricals) P F N/A

Hydrants, wet/dry risers & hose reels

  • 6.Landing valves and hose-reel drums accessible, not blocked P F N/A
  • 7.Hoses, nozzles and couplings present and undamaged P F N/A
  • 8.Pump / jockey pump on auto; no fault lamps at the panel P F N/A
  • 9.Fire-brigade inlet connection clear and capped P F N/A
  • 10.Water storage / tank level adequate per the design P F N/A

Fire detection & alarm

  • 11.Panel shows normal — no fault, disable or isolate conditions P F N/A
  • 12.Test one manual call point and confirm sounders in that zone P F N/A
  • 13.Detectors unpainted, undamaged and not covered P F N/A
  • 14.Standby battery healthy and holding charge P F N/A
  • 15.Log the test, zone and result P F N/A

Emergency & escape lighting

  • 16.Flick-test / test-switch and confirm fittings come on P F N/A
  • 17.No failed, dim or flickering emergency fittings P F N/A
  • 18.Exit signs illuminated and visible along the route P F N/A
  • 19.Rated duration confirmed OK at the last full-discharge test P F N/A

Means of escape

  • 20.Exit doors unlocked / openable from inside without a key P F N/A
  • 21.Routes and staircases clear of storage and obstruction P F N/A
  • 22.Final exit doors open easily to the open air P F N/A
  • 23.Doors on high-occupancy rooms swing in the escape direction P F N/A
  • 24.No locked, chained or blocked staircases or exits P F N/A

Signage & fire plan

  • 25.Running-man exit signs present at changes of direction P F N/A
  • 26.Extinguisher, hydrant and assembly-point signs in place P F N/A
  • 27.Fire-action notice / evacuation plan displayed and legible P F N/A
  • 28.Photoluminescent signs charge and glow in a darkness check P F N/A

Housekeeping & fire load

  • 29.No combustible clutter in corridors, lobbies or under stairs P F N/A
  • 30.Flammable liquids/gas stored correctly and away from ignition P F N/A
  • 31.Waste removed; no accumulation near electrical panels P F N/A
  • 32.Smoking restricted to designated areas only P F N/A

Electrical fire risk

  • 33.Distribution boards closed, labelled and unobstructed P F N/A
  • 34.No overloaded sockets, daisy-chained boards or loose plugs P F N/A
  • 35.No scorching, burning smell or overheating at fittings P F N/A
  • 36.Cables undamaged; no temporary/exposed wiring in use P F N/A
Any FAIL → note the location, act immediately and escalate. Signed:  

Life-safety notice. This is a self-inspection aid to help you build a routine — it is not a statutory fire audit, a Fire-NOC inspection, or a competent-person certification. Those must be carried out by a licensed fire officer / competent person under the National Building Code (NBC, SP 7:2026) / NBC Part 4 and your local fire rules, and the local fire officer / AHJ signs off. The right scope of checks depends on your building’s occupancy classification, height and the AHJ — verify everything against the applicable code and your fire consultant. Keep dated, signed inspection records. Fix or escalate any fail immediately — never sign off a life-safety fault. A wrong call here can cost lives.