Fire Door Checker

Fire Door Requirement Checker

Pick your building type, the element, and the occupant load. See where a fire door is required, its minimum rating (IS 3614), and the egress hardware — self-closer, panic bar and swing direction — under NBC 2016. Indicative India 2026; your fire consultant and the AHJ make the binding call.

120MIN

Your situation

Above 15 m — strict NBC compartmentation.

The protected escape shaft — usually the highest rating on site.

Wider leaf or a leaf-and-a-half for flow.

Ratings follow IS 3614 (30 / 60 / 90 / 120 min); egress and hardware follow NBC 2016 Part 4. This is a planning aid — the project architect and Fire NOC / AHJ decide the binding requirement.

Required fire rating

0 min

IS 3614 fire-check door · stairwell / fire-escape door in a residential high-rise

Self-closing device

Required — overhead closer

Panic / push-bar hardware

Standard lever / lock is fine

Swing direction

Opens OUT, in escape direction

Egress / escape route

Yes — part of the protected route

Indicative clear egress width 1200 mm (single or 1.5-leaf). Final width is set by the calculated occupant load per NBC unit-exit-width rules.

IS 3614 rating scale — your match highlighted

Why this rating: The protected escape shaft — usually the highest rating on site. Above 15 m — strict NBC compartmentation. The result is the strictest of the element minimum, the building base and the occupant-load uplift, snapped to the nearest IS 3614 rung.

Guidance only, not certification. Fire-door requirements, ratings and exit widths in India are set by NBC 2016 Part 4, IS 3614, the State Fire Service rules and the local Fire NOC / AHJ. Always have a licensed fire consultant confirm the binding specification before procurement or installation.