Fire Door Compliance Checker

Fire Door Compliance Checker

Enter your measured leaf gaps and confirm the seals, self-closer, signage and a certified set — get a PASS / FAIL verdict against NBC 2016 and IS 3614, with every failing item listed.

Life-safety screening only. A fire door protects escape routes and saves lives — this tool is guidance, never a substitute for inspection by a qualified fire-door installer or competent person.

Your fire door

Measured leaf gaps (mm) — target ≤3mm, 4mm max

mm
mm
mm
mm

Components present?

Gaps should be measured with a feeler gauge along the leaf perimeter. A tested fire-door set (leaf + frame + intumescent + smoke seal + self-closer + fire-rated hinges) is certified as a whole — swapping any component can void the rating. Indicative against NBC 2016 / IS 3614.

FD30 compliance verdict

PASS

0%

9 of 9 checks pass · 0 fail

All screened items meet the FD30 requirement. Still arrange a documented inspection by a competent person and keep the certification on file.

Measured leaf gaps vs the 3mm target (red dashed line)

Threshold uses its own ≤10mm (or sealed) limit. Indicative — confirm on a certified survey.

Full fire-door checklist (NBC 2016 / IS 3614)

  • Head gap

    3mm — within the ≤3mm target.

    Pass
  • Hinge-stile gap

    3mm — within the ≤3mm target.

    Pass
  • Lock-stile gap

    3mm — within the ≤3mm target.

    Pass
  • Threshold (bottom) gap

    8mm bottom gap is within the ≤10mm target.

    Pass
  • Continuous intumescent seal

    Intumescent strip fitted to leaf or frame, continuous around the leaf.

    Pass
  • Cold-smoke seal

    Brush / fin smoke seal present to resist cold smoke spread.

    Pass
  • Self-closing device

    Overhead / concealed closer fully closes and latches the leaf from any angle.

    Pass
  • 'Fire door keep shut' signage

    Mandatory signage fitted both faces (or 'Fire door keep locked' where applicable).

    Pass
  • Certified / tested door set

    Leaf, frame and hardware are a tested, certified set with a data / certification sheet.

    Pass

Plan the fire-door remediation

DesignAI can prioritise the failing items, suggest the right seals and closer, and tell you what to ask the fire-door installer or competent person to certify.

How this check works & its limits

A fire door only protects escape routes when the whole set works as tested. The screen above applies the core requirements drawn from NBC 2016 (National Building Code of India, fire & life-safety provisions) and IS 3614 (metallic & non-metallic fire-check doors): perimeter leaf gaps of ≤3mm (4mm absolute maximum) at head and stiles; a threshold gap ≤8–10mm or bridged by an approved threshold / drop seal; a continuous intumescent seal plus a cold-smoke seal where smoke control is required; a working self-closing device; "Fire door keep shut" signage; and a tested, certified door set with its data sheet.

Assumptions: a single-leaf swing door with three or more fire-rated hinges; gaps measured with a feeler gauge; FD30 / FD60 leaf and frame matched to the certification. This is indicative — gap tolerances, smoke-seal requirements and signage vary by the specific test certificate, the building's fire strategy and the local fire NOC. Confirm with your carpenter / fitter on site and have a qualified fire-door installer or competent person carry out and document the inspection.

No prices are shown here; where fire-door supply, sealing or remediation is quoted separately, GST at 18% applies on the works. This is a guidance tool, not a substitute for a qualified fire-door inspection or your authority's fire approval.